Call Us Now
+965 22432132 - 22410172
Send Us Mail
info@ideal-sys.com
Work Time
Sun-Th 8 am - 5 pm
OM-120

OM-120


DESCRIPTION

A. The multi-output module, capable of configuring and controlling zones or floors with BioStar 2.

B. Support 12 relay outputs per module.

FEATURES

A. Control up to 192 floors per elevator with BioStar 2 when connected as daisy chains via RS-485.

B. Capable of setting the floor access privilege in BioStar 2 when connected Biometric/RFID devices.

C. Switchable on-board RS-485 termination.

D. Interlock with Anti-passback zones and Fire Alarm zones, manage to occur specific outputs when an alarm is triggered.

E. RS-485, AUX Input, Relay.



 

SPECIFICATIONS 

Category 

Feature 

Specification 

General 

CPU 

Cortex M3 72MHz  

Memory 

Flash 128KB, SRAM 20KB 

LED 

Multi-color  

 - Power 1 ea 

 - Relays 12 ea 

 - RS-485 2 ea 

 - AUX IN 2 ea 

 - Status 1 ea 

Operating temperature 

-20°C ~ 60°C 

Storage temperature 

-40°C ~ 70°C 

Operating humidity 

0% ~ 95%, non-condensing 

Storage humidity 

0% ~ 95%, non-condensing 

Dimension (W x H x D) 

90 mm x 190 mm x 21 mm 

Weight 

300 g 

Certificates 

CE, FCC, KC, RoHS, REACH, WEEE 

Interface 

RS-485 

1ch 

AUX input 

2ch Dry Contact Input 

Relay 

12 Relays 

Electrical 

Power 

Voltage: 12 VDC  

Current: Max. 1 A 

Switch input VIH 

Max. 5 V (Dry Contact) 

Relay  

Voltage: Max. 30 VDC 

Current: Max. 5 A 



Click To Watch Video

Related Product

Chat With Support